Note: The HPCI Barrier Panel must be separated from the interior of the building by an approved thermal barrier of .5" (12.7mm) gypsum wallboard to meet IBC requirements.
Exterior Profile: | No profile embossed | |||
Interior Profile: | Light Mesa embossed | |||
Foam Core: | Foamed-in-place, Non-CFC & zero ODP polyurethane, FM Class 1 approval. | |||
Thermal Values: | R-Values with Air Films | 75° Mean | 40° Mean | |
2" Panel | 15.14 | 17.03 | ||
3" Panel | 22.27 | 25.55 | ||
4" Panel | 29.42 | 34.06 | ||
R-Values include the air films on each side of the panel. 75° Mean based on ASTM C518 Thermal Testing. 40° Mean based on ASTM C1363 Thermal Testing (Values for C1363 based on 4" panel testing). All values for other thicknesses extrapolated. |
||||
Module Width: | 42" | |||
Panel Thickness: | 2", 3", 4" | |||
Panel Lengths: | 8'-0" to 24'-0" | |||
Horizontal Application Reveal Widths: | 1/4", 1/2", 3/4", 1", 1-1/2", 2", 2-1/2", 3" | |||
Exterior Facings & Interior Facings: | Minimum .016″ thick HPCI galvanized steel | |||
Color: | White polyester | |||
Joint: | Offset double tongue and groove with extended metal shelf for positive face fastening. | |||
Note: | Offset double tongue and groove with extended metal shelf for positive face fastening. |